<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "https://jats.nlm.nih.gov/publishing/1.3/JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xml:lang="ru">
  <front>
    <journal-meta>
      <journal-id journal-id-type="elibrary">https://www.elibrary.ru/title_about_new.asp?i</journal-id>
      <journal-title-group>
        <journal-title>Global Energy</journal-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Глобальная энергия</trans-title>
        </trans-title-group>
      </journal-title-group>
      <issn pub-type="epub">2782-6724</issn>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id">7</article-id>
      <title-group>
        <article-title>Automation limited reduce the voltage in the power system for metropolis</article-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Автоматика ограничения снижения напряжения в энергосистемах мегаполисов</trans-title>
        </trans-title-group>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Kravcheko</surname>
            <given-names>Ilya</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Kostin</surname>
            <given-names>Vlaimir</given-names>
          </name>
          <email>kostin_vn@mail.ru</email>
        </contrib>
      </contrib-group>
      <pub-date publication-format="electronic" date-type="pub" iso-8601-date="2011-12-10">
        <day>10</day>
        <month>12</month>
        <year>2011</year>
      </pub-date>
      <issue>4</issue>
      <issue-id pub-id-type="publisher-id">135</issue-id>
      <fpage>58</fpage>
      <lpage>63</lpage>
      <abstract xml:lang="en">
        <p>The algorithms and the fundamental functionality of the microprocessor circuit of the automatic voltage reduction limits. The device allows the introduction of mode voltage in the acceptable range to minimize the amount of load shedding. Grounded and provides blocking of the device during short circuits.</p>
      </abstract>
      <kwd-group xml:lang="ru">
        <kwd>НАДЕЖНОСТЬ ЭЛЕКТРОСНАБЖЕНИЯ</kwd>
        <kwd>ОТКЛЮЧЕНИЕ НАГРУЗКИ</kwd>
        <kwd>РЕЗЕРВ МОЩНОСТИ</kwd>
        <kwd>ЛАВИНА НАПРЯЖЕНИЯ</kwd>
      </kwd-group>
    </article-meta>
  </front>
</article>