<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "https://jats.nlm.nih.gov/publishing/1.3/JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xml:lang="ru">
  <front>
    <journal-meta>
      <journal-id journal-id-type="elibrary">https://www.elibrary.ru/title_about_new.asp?i</journal-id>
      <journal-title-group>
        <journal-title>Global Energy</journal-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Глобальная энергия</trans-title>
        </trans-title-group>
      </journal-title-group>
      <issn pub-type="epub">2782-6724</issn>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id">9</article-id>
      <title-group>
        <article-title>Effect of the energy characteristics of the nonlinear load to determine the electrical parameters</article-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Влияние энергетических характеристик нелинейной нагрузки на определение параметров электрической сети</trans-title>
        </trans-title-group>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Shkliarsky</surname>
            <given-names>Jaroslav</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Dobush</surname>
            <given-names>Vasiliy</given-names>
          </name>
          <email>griimov@yandex.ru</email>
        </contrib>
      </contrib-group>
      <pub-date publication-format="electronic" date-type="pub" iso-8601-date="2012-12-10">
        <day>10</day>
        <month>12</month>
        <year>2012</year>
      </pub-date>
      <issue>4</issue>
      <issue-id pub-id-type="publisher-id">159</issue-id>
      <fpage>77</fpage>
      <lpage>80</lpage>
      <abstract xml:lang="en">
        <p>The paper analyzes the influence of the energy characteristics of the nonlinear load calculation of the circuit parameters. On the basis of the example circuit is designed error of equivalent circuits with non-linear load and without the phase-angles between the current and voltage at the higher harmonics.</p>
      </abstract>
      <kwd-group xml:lang="en">
        <kwd>NONLINEAR LOAD</kwd>
        <kwd>HARMONICS</kwd>
        <kwd>MODELING</kwd>
        <kwd>POWER ELECTRONICS</kwd>
        <kwd>EQUIVALENT CIRCUIT</kwd>
      </kwd-group>
    </article-meta>
  </front>
</article>