<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "https://jats.nlm.nih.gov/publishing/1.3/JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xml:lang="ru">
  <front xmlns:xlink="http://www.w3.org/1999/xlink">
    <journal-meta>
      <journal-id journal-id-type="elibrary">https://www.elibrary.ru/title_about_new.asp?i</journal-id>
      <journal-title-group>
        <journal-title>Global Energy</journal-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Глобальная энергия</trans-title>
        </trans-title-group>
      </journal-title-group>
      <issn pub-type="epub">2782-6724</issn>
    </journal-meta>
    <article-meta xmlns:xlink="http://www.w3.org/1999/xlink">
      <article-id pub-id-type="publisher-id">6</article-id>
      <article-id pub-id-type="doi">10.18721/JEST.27306</article-id>
      <title-group>
        <article-title>ONLINE DIAGNOSTICS OF THE ACTIVE PART OF POWER TRANSFORMERS</article-title>
        <trans-title-group xml:lang="ru">
          <trans-title>ОНЛАЙН ДИАГНОСТИКА АКТИВНОЙ ЧАСТИ СИЛОВЫХ ТРАНСФОРМАТОРОВ</trans-title>
        </trans-title-group>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Poliakov</surname>
            <given-names>Valeriy</given-names>
          </name>
        </contrib>
      </contrib-group>
      <pub-date publication-format="electronic" date-type="pub" iso-8601-date="2021-09-30">
        <day>30</day>
        <month>09</month>
        <year>2021</year>
      </pub-date>
      <volume>27</volume>
      <issue>3</issue>
      <fpage>63</fpage>
      <lpage>76</lpage>
      <self-uri xmlns:xlink="http://www.w3.org/1999/xlink" content-type="pdf" xlink:href="https://engtech.spbstu.ru/userfiles/files/articles/2021/3/Polyakov.pdf"/>
      <abstract xml:lang="en">
        <p>The paper describes a method for obtaining the characteristics of the active part of power transformers online. The method is based on the processing of digital current and voltage wave-forms obtained at turning on of unloaded transformer with premagnetized core. The core of transformer, switched off by a circuit breaker, has residual induction value closing to nominal Bn = 1.5. Switching on of the transformer leads to addition of working AC field to residual one. Therefore full magnetic field may achieves saturation induction B = 3 T. In this case winding cur-rent is close to shorting one Idemag = (5-6)In. It let's to build magnetization curve – dependence of the magnetic flux on winding current. This dependence let's to get all the parameters of the active part of the transformers, which are usually measured on a disconnected transformer using an external voltage source.</p>
      </abstract>
      <kwd-group xml:lang="en">
        <kwd>Power transformer</kwd>
        <kwd>magnet circuit</kwd>
        <kwd>waveform</kwd>
        <kwd>unloaded mode</kwd>
        <kwd>demagnetization</kwd>
        <kwd>saturation induction</kwd>
        <kwd>magnetization curve</kwd>
        <kwd>active part parameters</kwd>
      </kwd-group>
    </article-meta>
  </front>
</article>
