Extra turbine power through the use of diffused after the last stage
Authors:
Abstract:
Considered a one-dimensional adiabatic flow of a perfect gas in the flow part of the last turbine stage and the diffuser, which located after it. Obtained a simple engineering formula to measure an additiona-1 power of the turbine through the use of the diffuser, which is located behind the last stage.