<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "https://jats.nlm.nih.gov/publishing/1.3/JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xml:lang="en">
  <front>
    <journal-meta>
      <journal-id journal-id-type="elibrary">https://www.elibrary.ru/title_about_new.asp?i</journal-id>
      <journal-title-group>
        <journal-title>Global Energy</journal-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Глобальная энергия</trans-title>
        </trans-title-group>
      </journal-title-group>
      <issn pub-type="epub">2782-6724</issn>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id">10</article-id>
      <title-group>
        <article-title>REDUCTION IN THE CURRENT DRAIN  BY THE INSTALLATIONS OF CATHODIC PROTECTION</article-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Снижение потребления тока  установками катодной защиты от коррозии</trans-title>
        </trans-title-group>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Kiselev</surname>
            <given-names>Vladimir</given-names>
          </name>
          <email>kis_vg@mail.ru</email>
        </contrib>
      </contrib-group>
      <pub-date publication-format="electronic" date-type="pub" iso-8601-date="2013-12-10">
        <day>10</day>
        <month>12</month>
        <year>2013</year>
      </pub-date>
      <issue>4</issue>
      <issue-id pub-id-type="publisher-id">183</issue-id>
      <issue-part>1</issue-part>
      <fpage>93</fpage>
      <lpage>99</lpage>
      <abstract xml:lang="en">
        <p>In the article is produced the analysis and the systematization of the basic factors, which have an effect on current drain by the system for the cathode protection of underground metallic communications from corrosion. The basic reasons, which have an effect on the current drain and power loss in the direct-current circuit of electrochemical corrosion protection, are in detail examined and systematized, and practical recommendations regarding their decrease are given.</p>
      </abstract>
      <kwd-group xml:lang="en">
        <kwd>CORROSION. ELECTROCHEMICAL CORROSION. CATHODIC PROTECTION. ELECTROCHEMICAL CORROSION PROTECTION. PROTECTION FROM THE EXTERNAL CORROSION OF UNDERGROUND METALLIC COMMUNICATIONS.</kwd>