<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "https://jats.nlm.nih.gov/publishing/1.3/JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xml:lang="en">
  <front>
    <journal-meta>
      <journal-id journal-id-type="elibrary">https://www.elibrary.ru/title_about_new.asp?i</journal-id>
      <journal-title-group>
        <journal-title>Global Energy</journal-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Глобальная энергия</trans-title>
        </trans-title-group>
      </journal-title-group>
      <issn pub-type="epub">2782-6724</issn>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id">7</article-id>
      <article-id pub-id-type="doi">10.18721/JEST.230407</article-id>
      <title-group>
        <article-title>ANALYSIS OF OPERATING CONDITIONS AND STABILITY OF INTERCONNECTIONS BASED ON FLEXIBLE AC TRANSMISSION LINES WITH CONTROLLED SERIES AND SHUNT COMPENSATION DEVICES</article-title>
        <trans-title-group xml:lang="ru">
          <trans-title>ИССЛЕДОВАНИЕ РЕЖИМОВ И УСТОЙЧИВОСТИ МЕЖСИСТЕМНОЙ СВЯЗИ НА ОСНОВЕ ГИБКОЙ ЛИНИИ ЭЛЕКТРОПЕРЕДАЧИ ПЕРЕМЕННОГО ТОКА С УПРАВЛЯЕМОЙ ПРОДОЛЬНОЙ И ПОПЕРЕЧНОЙ КОМПЕНСАЦИЕЙ</trans-title>
        </trans-title-group>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Khazov</surname>
            <given-names>Maksim</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Chernyaev</surname>
            <given-names>Piotr</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Belyaev</surname>
            <given-names>Andrey</given-names>
          </name>
          <email>andrey.belyaev@gmail.com</email>
        </contrib>
      </contrib-group>
      <pub-date publication-format="electronic" date-type="pub" iso-8601-date="2017-12-10">
        <day>10</day>
        <month>12</month>
        <year>2017</year>
      </pub-date>
      <volume>23</volume>
      <issue>4</issue>
      <fpage>74</fpage>
      <lpage>88</lpage>
      <abstract xml:lang="en">
        <p>The paper describes a study on the operating conditions and small signal stability of flexible AC transmission lines with controlled series and shunt compensation. It is shown that the installation of controllable shunt compensation devices in addition to the existing series allows to increase the transmission power limit by almost two times, provided that the voltage levels are kept within the permissible limits. The minimally possible optimal composition and location of the controlled shunt compensation devices is established to ensure the operation of power transmission in a wide range of power transmission. A set of measures aimed at increasing the static stability margin is justified. The joint coordination of tuning parameters of the series and shunt control devices is implemented.</p>
      </abstract>
      <kwd-group xml:lang="en">
        <kwd>FLEXIBLE ALTERNATIVE CURRENT TRANSMISSION SYSTEM</kwd>
        <kwd>THRYSTOR CONTROLLED SERIES COMNESATION</kwd>
        <kwd>SMALL SIGNAL STABILITY</kwd>
        <kwd>CONTROLLED SHUNT REACTOR</kwd>
        <kwd>STATIC VAR COMPENSATOR</kwd>
      </kwd-group>