<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "https://jats.nlm.nih.gov/publishing/1.3/JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xml:lang="en">
  <front xmlns:xlink="http://www.w3.org/1999/xlink">
    <journal-meta>
      <journal-id journal-id-type="elibrary">https://www.elibrary.ru/title_about_new.asp?i</journal-id>
      <journal-title-group>
        <journal-title>Global Energy</journal-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Глобальная энергия</trans-title>
        </trans-title-group>
      </journal-title-group>
      <issn pub-type="epub">2782-6724</issn>
    </journal-meta>
    <article-meta xmlns:xlink="http://www.w3.org/1999/xlink">
      <article-id pub-id-type="publisher-id">2</article-id>
      <article-id pub-id-type="doi">10.18721/JEST.240102</article-id>
      <title-group>
        <article-title>Differential protection of inter-system transmission lines with charge capacity compensation</article-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Дифференциальная защита межсистемных линий электропередачи с компенсацией зарядной мощности</trans-title>
        </trans-title-group>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Popov</surname>
            <given-names>Maxim</given-names>
          </name>
        </contrib>
      </contrib-group>
      <pub-date publication-format="electronic" date-type="pub" iso-8601-date="2018-03-30">
        <day>30</day>
        <month>03</month>
        <year>2018</year>
      </pub-date>
      <volume>24</volume>
      <issue>1</issue>
      <fpage>17</fpage>
      <lpage>26</lpage>
      <self-uri xmlns:xlink="http://www.w3.org/1999/xlink" content-type="pdf" xlink:href="https://engtech.spbstu.ru/userfiles/files/articles/2018/2/2.pdf"/>
      <abstract xml:lang="en">
        <p>The goal of the article was to investigate the dynamic properties of longitudinal differential protection of power lines with charge capacity compensation and to develop recommendations for increasing the sensitivity of protection. As a result of the study, it was established that the minimum tripping current of the protection is inadmissible for providing selective operation due to the condition of sensitivity in idle switching modes of the OL. Therefore, an increase in the main braking signal is necessary in order to achieve the required sensitivity and speed. The article presents the results of an evaluation of the effectiveness of the methods proposed earlier in [1] for improving the efficiency of protection. The use of additional braking due to compensation of unbalance currents caused by distributed capacitance of the OL allows to significantly increase the sensitivity of protection.</p>
      </abstract>
      <kwd-group xml:lang="en">
        <kwd>Electric transmission line</kwd>
        <kwd>current transformer</kwd>
        <kwd>dynamic properties</kwd>
        <kwd>differential protection</kwd>
        <kwd>restricted signal</kwd>
        <kwd>correction of sensitivity</kwd>
      </kwd-group>